How accurate is a sound level meter app?
A sound level meter app can give useful, repeatable numbers, or numbers that are 10 dB out. The difference comes from the microphone, what the phone does to the audio before an app sees it, and whether the app uses the standard weightings and averages. This page explains the terms, what is known about phone accuracy, and a short checklist for readings you can rely on.
Frequency weightings: dBA, dBC and dBZ
| Weighting | What it does | Used for |
|---|---|---|
| A (dBA) | Turns down low and very high frequencies, roughly as the ear hears moderate sounds | Noise exposure at work, environmental and neighbour noise, most noise rules |
| C (dBC) | Nearly flat, turns down only the extremes, so it keeps the bass | Peak sound pressure limits, low-frequency and bass noise, setting speaker levels |
| Z (dBZ) | Flat: no weighting | Seeing everything the microphone picks up, octave-band analysis |
Time weightings and averages
| Term | Meaning |
|---|---|
| Fast (F) | The reading responds with a 125 ms time constant: follows quick changes |
| Slow (S) | 1 second time constant: steadier; OSHA measures on the A scale at slow response |
| Impulse (I) | Rises fast, falls slowly, for short bangs |
| Leq / LAeq | The steady level with the same sound energy as the changing noise over the measurement time; LAeq is the A-weighted one and the basis of daily noise exposure |
| Max | The highest time-weighted level during the measurement |
| Peak | The highest instantaneous sound pressure, not time-weighted; workplace peak limits are in dB(C) |
Why raw audio matters on a phone
Phones are built for calls. Before an app receives the microphone signal, the operating system can run echo cancellation, noise suppression and automatic gain control. These make voices clearer and also turn steady background noise down and quiet sounds up, which is exactly what a sound level meter must not do.
dB Logger asks the phone for its unprocessed measurement input, so the level it shows follows the sound rather than the call-processing.
What is known about phone accuracy
Professional sound level meters are tested to IEC 61672-1, which sets Class 1 and Class 2 tolerances [1]. A phone is not certified to either class.
In 2014 NIOSH researchers evaluated smartphone sound measurement apps against a professional Type 1 meter and found that only a few of them agreed within 2 dB; the better results came from apps on iOS [2]. NIOSH later released its own iPhone app and says it is not meant to replace a professional meter or dosimeter or for compliance, and recommends a calibrated external microphone [3].
What this means in practice: a calibrated phone with a raw input can be good for screening, comparing and documenting; an uncalibrated phone through call-processing can be badly wrong.
Checklist for readings you can trust
- Calibrate against a known reference: a sound level calibrator, or a certified meter next to the phone.
- Calibrate each microphone separately; the built-in mic and a USB-C measurement mic behave differently.
- Keep the microphone uncovered, the phone still and away from your body, and out of a case that blocks the mic.
- Choose the right weighting: A for noise exposure and neighbour noise, C for bass and peaks.
- Log a period and use Leq, not a single glance at the needle.
- Write down where and when you measured, and what the noise was.
- For legal or compliance decisions, use certified instruments.
How dB Logger handles this
dB Logger measures A, C and Z weighting with Fast, Slow and Impulse response, shows Leq, Max and Peak, and keeps a guided or manual calibration per microphone profile, including external USB-C measurement microphones. It logs to CSV and lossless WAV so a measurement can be checked again later.
Sources
- IEC 61672-1:2013 Electroacoustics, Sound level meters, Part 1: Specifications
- Kardous C.A., Shaw P.B. (2014), Evaluation of smartphone sound measurement applications, J. Acoust. Soc. Am. 135(4) EL186
- NIOSH Sound Level Meter app
- OSHA 29 CFR 1910.95, Occupational noise exposure (A scale, slow response)
dB Logger is not a certified Class 1 or Class 2 sound level meter. Its readings are for screening, comparison and documentation; use certified instruments for legal, contractual or compliance measurements.