Workplace noise limits: OSHA, NIOSH and the UK Noise at Work Regulations

Four sets of numbers come up whenever someone asks whether a workplace is too loud: the US OSHA rule, the NIOSH recommendation, the EU directive and the UK regulations that follow it. They use different levels, different exchange rates and different ways of adding up a day. This page sets them side by side, shows how a dosimeter turns a day of changing noise into one number, and says plainly what a phone measurement is good for.

The limits side by side

RuleDaily levelExchange ratePeakWhat it means
OSHA 29 CFR 1910.95, permissible exposure limit (US law)90 dBA, 8-hour TWA5 dB140 dB peak (impulsive or impact noise)Above it the employer must reduce exposure; levels measured on the A scale at slow response [1]
OSHA 29 CFR 1910.95(c), action level (US law)85 dBA, 8-hour TWA (a dose of 50 %)5 dBA hearing conservation programme is required [1]
NIOSH recommended exposure limit (US guidance, not law)85 dBA, 8-hour TWA3 dBExposure at or above it is considered hazardous [2]
UK Control of Noise at Work Regulations 2005, lower exposure action values (Great Britain)80 dB(A) daily or weekly exposure3 dB (energy based)135 dB(C)The employer must assess the risk to workers' health and provide information and training [3][4]
UK upper exposure action values85 dB(A)3 dB137 dB(C)The employer must provide hearing protection and hearing protection zones [3][4]
UK exposure limit values87 dB(A)3 dB140 dB(C)Must not be exceeded; unlike the action values, this one takes the hearing protection worn into account [3]
EU Directive 2003/10/EC80 / 85 / 87 dB(A)3 dB135 / 137 / 140 dB(C)The same three tiers as the UK regulations, which were written to implement it [5]

Why the same day can pass one rule and fail another

The exchange rate is how much louder the noise can be for half the time. OSHA uses 5 dB: 95 dBA is allowed for 4 hours, 100 dBA for 2. NIOSH, the EU and the UK use 3 dB, the equal-energy rule: 88 dBA for 4 hours carries the same sound energy as 85 dBA for 8. A 3 dB rule is stricter for loud, short work.

OSHA also ignores quieter sound: for the permissible limit, levels below 90 dBA do not add to the dose, and for the action level, levels below 80 dBA do not. The EU and UK measure, LEX,8h, counts every second of the working day.

How a dosimeter adds up a day

For OSHA and NIOSH style limits, each level L has an allowed time T = 8 hours / 2^((L − criterion level) / exchange rate). The dose is the sum of the time spent at each level divided by its allowed time, as a percentage; 100 % means the limit has been reached. The time-weighted average (TWA) is the criterion level + exchange rate × log2(dose / 100 %).

For the EU and UK, the daily personal noise exposure is LEX,8h = LAeq,Te + 10 × log10(Te / 8 hours), where LAeq,Te is the A-weighted equivalent continuous level over the time Te actually worked.

These are the formulas dB Logger's dosimeter uses for its NIOSH, OSHA and EU profiles.

Worked example: 4 hours at 88 dBA and 4 hours at 82 dBA

RuleResultReading
NIOSH REL (85 dBA, 3 dB)Dose 125 %, TWA 86.0 dBAOver the recommended limit
OSHA action level (80 dBA threshold, 90 dBA criterion, 5 dB)Dose 54 %, TWA 85.6 dBAAbove the action level: hearing conservation programme
OSHA PEL (90 dBA threshold, 5 dB)Dose 0 %Every level is below 90 dBA, so nothing counts
UK / EU LEX,8h86.0 dB(A)Above the upper action value of 85, below the limit value of 87

What a phone can and cannot tell you

A phone is not a certified Class 1 or Class 2 sound level meter under IEC 61672-1, and it is not a personal noise dosimeter worn at the ear. NIOSH, which publishes its own iPhone sound level meter app, says its app is not meant to replace a professional sound level meter or dosimeter or to be used for compliance, and recommends a calibrated external microphone [6].

What a phone is good for: - finding out quickly which tasks, rooms or machines are near 80 or 85 dB(A); - comparing before and after a change, such as an enclosure or a quieter tool; - showing people how loud their work is and how fast a dose builds up; - deciding where a proper survey with certified instruments and a competent person is needed.

Doing this with dB Logger

dB Logger's dosimeter has NIOSH, OSHA permissible-limit, OSHA action-level and EU (LEX,8h) profiles and shows the dose, the projected 8-hour figure and the level measured so far. Calibrate the microphone first, keep the phone still and its microphone uncovered, and log the session to CSV so the numbers can be checked later. An external USB-C measurement microphone with its own calibration profile gets closer to a meter's behaviour than the built-in mic.

Sources

  1. OSHA 29 CFR 1910.95, Occupational noise exposure (Table G-16, paragraph (b)(1) slow response, (c)(1) action level, 140 dB peak)
  2. NIOSH, Criteria for a Recommended Standard: Occupational Noise Exposure, Revised Criteria 1998 (Publication 98-126) (REL 85 dBA 8-hour TWA, 3 dB exchange rate)
  3. The Control of Noise at Work Regulations 2005, regulation 4: exposure limit values and action values (Extends to England, Wales and Scotland)
  4. HSE: Noise at work, the regulations
  5. Directive 2003/10/EC on the minimum health and safety requirements regarding exposure of workers to noise
  6. NIOSH Sound Level Meter app

This page explains published limits in plain words and is not legal or occupational-health advice. Check the current text of the rule that applies to you, and use certified instruments and a competent person for a noise risk assessment or compliance decision.

Back to dB Logger